Tripp Lite SU6000RT4UHVHW uninterruptible power supply (UPS) 6 kVA 5400 W

Tripp Lite SU6000RT4UHVHW. Output power capacity: 6 kVA, Output power: 5400 W, Input operation voltage (min): 200 V. Typical backup time at full load: 2 min, Typical backup time at half load: 8.5 min, Battery recharge time: 6 h. Form factor: Rackmount, Product color: Black, Rack capacity: 4U. Width: 17.5" (445 mm), Depth: 20.7" (526 mm), Height: 6.85" (174 mm). Master (outer) case width: 23.6" (599.4 mm), Master (outer) case length: 29.1" (739.1 mm), Master (outer) case height: 12.7" (322.6 mm)
Manufacturer: Tripp Lite
SKU: 2711761
Manufacturer part number: SU6000RT4UHVHW
GTIN: 0037332157089
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Featuring true on-line operation with pure sine wave output, zero transfer time to battery and complete UPS replacement capability with no downtime, the SU6000RT4UHVHW provides the highest level of protection available for mission-critical equipment from power outages, voltage fluctuations and transient surges. It converts incoming AC power to DC, and re-converts it back to filtered AC output with a pure sine wave, isolating connected components from all power problems in high-voltage environments. The SU6000RT4UHVHW has a 6kVA/5400W capacity and hardwire output. With its detachable PDU with bypass switch, the SU6000RT4UHVHW is easily hot-swappable by a user of any skill set—no need for lengthy and expensive service calls, and no downtime if a repair or battery replacement is needed. In bypass mode, the PDU passes power to equipment without the use of the power and battery modules, allowing them to be removed while keeping your application in operation. UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The SU6000RT4UHVHW’s runtime can be expanded with optional external battery packs. The SU6000RT4UHVHW features a highly efficient (96%) economy mode setting that can significantly reduce a facility's energy costs by minimizing heat output, reducing cooling requirements and consuming less electricity. An LCD display with LED indicators enables IT personnel to operating modes and conditions. The LCD/LED panel rotates for viewing in horizontal rack or vertical tower installations and includes an audible alarm that signals various conditions. The SU6000RT4UHVHW features a USB port and a DB9 ports for comprehensive network power monitoring and control. Network management card options available. The unit requires only 4U of rack space in a standard rack enclosure and can be installed in a 2-post rack using the 2POSTRMKITHD accessory, or in a tower configuration with the 2-9USTAND accessory. The SU6000RT4UHVHW comes with $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only) for connected equipment. Tripp Lite SU6000RT4UHVHW 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system in a single 4U rack/tower compatible housing Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions Detachable back panel PDU contains hardwire input and output connections, plus manual bypass switch to support hot-swappable whole UPS replacement with no interruption to connected equipment Hardwire input and output connections supported Included rail kit supports 4U 19 inch rackmount installation in 4 post racks Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (1 required for SU6000RT4UHVHW) Optional 2-9USTAND supports upright tower placement (1 required for SU6000RT4UHVHW) Maximum installed rack depth of only 20.7 in. / 52.6cm inches Maintains full-time sine wave output within 2% of selected 200/208/220/230/240V nominal in double conversion mode Corrects brownouts to 156V at full load (100V at 50% load or less) Corrects overvoltages to 290V at full load (300V at 90% load or less) Supports 50/60Hz operation for worldwide frequency compatibility Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs Network-grade AC surge and noise suppression Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and network management card options Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD and RELAYIOCARD Optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities PADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module) HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS functions with support for a variety of control options to support advanced UPS settings and configurations LED/LCD display panel rotates for viewing in rackmount or tower configurations Supports Emergency Power Off (EPO) via built-in interface Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement BP192V12-3U external battery packs are field replaceable and hot swappable Intelligent battery management system with temperature-compensated charging extends battery life Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual) Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)

 

  • 6000VA / 6kVA / 5400W on-line double-conversion 4U rack/tower UPS, Sine Wave
  • Included maintenance bypass switch enables live replacement of UPS with zero downtime
  • Extended runtime options, Interactive LCD interface, Economy-mode option, 0.9 power factor
  • Add optional WEBCARDLX with latest version of PADM20 for enhanced remote management
  • Hardwire 200-240V 50/60Hz (3 wire) input; Hardwire (3 wire) output; Configurable for 200/208/220/230/240V 50/60Hz output
Featuring true on-line operation with pure sine wave output, zero transfer time to battery and complete UPS replacement capability with no downtime, the SU6000RT4UHVHW provides the highest level of protection available for mission-critical equipment from power outages, voltage fluctuations and transient surges. It converts incoming AC power to DC, and re-converts it back to filtered AC output with a pure sine wave, isolating connected components from all power problems in high-voltage environments. The SU6000RT4UHVHW has a 6kVA/5400W capacity and hardwire output. With its detachable PDU with bypass switch, the SU6000RT4UHVHW is easily hot-swappable by a user of any skill set—no need for lengthy and expensive service calls, and no downtime if a repair or battery replacement is needed. In bypass mode, the PDU passes power to equipment without the use of the power and battery modules, allowing them to be removed while keeping your application in operation. UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The SU6000RT4UHVHW’s runtime can be expanded with optional external battery packs. The SU6000RT4UHVHW features a highly efficient (96%) economy mode setting that can significantly reduce a facility's energy costs by minimizing heat output, reducing cooling requirements and consuming less electricity. An LCD display with LED indicators enables IT personnel to operating modes and conditions. The LCD/LED panel rotates for viewing in horizontal rack or vertical tower installations and includes an audible alarm that signals various conditions. The SU6000RT4UHVHW features a USB port and a DB9 ports for comprehensive network power monitoring and control. Network management card options available. The unit requires only 4U of rack space in a standard rack enclosure and can be installed in a 2-post rack using the 2POSTRMKITHD accessory, or in a tower configuration with the 2-9USTAND accessory. The SU6000RT4UHVHW comes with $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only) for connected equipment. Tripp Lite SU6000RT4UHVHW 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system in a single 4U rack/tower compatible housing Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions Detachable back panel PDU contains hardwire input and output connections, plus manual bypass switch to support hot-swappable whole UPS replacement with no interruption to connected equipment Hardwire input and output connections supported Included rail kit supports 4U 19 inch rackmount installation in 4 post racks Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (1 required for SU6000RT4UHVHW) Optional 2-9USTAND supports upright tower placement (1 required for SU6000RT4UHVHW) Maximum installed rack depth of only 20.7 in. / 52.6cm inches Maintains full-time sine wave output within 2% of selected 200/208/220/230/240V nominal in double conversion mode Corrects brownouts to 156V at full load (100V at 50% load or less) Corrects overvoltages to 290V at full load (300V at 90% load or less) Supports 50/60Hz operation for worldwide frequency compatibility Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs Network-grade AC surge and noise suppression Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and network management card options Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD and RELAYIOCARD Optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities PADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module) HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS functions with support for a variety of control options to support advanced UPS settings and configurations LED/LCD display panel rotates for viewing in rackmount or tower configurations Supports Emergency Power Off (EPO) via built-in interface Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement BP192V12-3U external battery packs are field replaceable and hot swappable Intelligent battery management system with temperature-compensated charging extends battery life Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual) Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)

 

  • 6000VA / 6kVA / 5400W on-line double-conversion 4U rack/tower UPS, Sine Wave
  • Included maintenance bypass switch enables live replacement of UPS with zero downtime
  • Extended runtime options, Interactive LCD interface, Economy-mode option, 0.9 power factor
  • Add optional WEBCARDLX with latest version of PADM20 for enhanced remote management
  • Hardwire 200-240V 50/60Hz (3 wire) input; Hardwire (3 wire) output; Configurable for 200/208/220/230/240V 50/60Hz output
Products specifications
Attribute nameAttribute value
Master (outer) case weight156.5 lbs
Master (outer) case height12.7"
Country of OriginChina
Width17.5"
Depth20.7"
Height6.85"
Weight116.4 lbs
Battery Recharge Time6 h
Emergency Power Off (EPO)Y
Input Frequency50/60 Hz
Display TypeLED
Power factor0.9
Number of phases1
Master (outer) case length29.1"
Master (outer) case width23.6"
EMI/RFI noise filteringY
Crest factor3:1
Features
Rack capacity4U
LED indicatorsY
Output power5400 W
Noise level60 dB
Audible alarm(s)Y
Input operation voltage (min)200 V
Input operation voltage (max)240 V
Output operation voltage (min)200 V
Output operation voltage (max)240 V
Efficiency96 %
Design
CertificationUL1778 CSA FCC Part 15 Category A IEC 61000-4-5 1995 B
Form factorRackmount
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 50 °C
Operating altitude0 - 118110.2"
Relative humidity0 - 95 %
Ports & interfaces
RS-232 ports1
USB 2.0 ports quantity1
Serial ports quantity1
Technical details
Product colorBlack
Sustainability certificatesRoHS
Management platformSNMP
Power
Maximum current40 A
Output power capacity6 kVA
Packaging data
Package weight156.5 lbs
Package width23.6"
Package depth29.1"
Package height12.7"
Logistics data
Quantity per master (outer) case1 pc(s)
Battery
Typical backup time at full load2 min
Typical backup time at half load8.5 min
Hot-swap batteryY
*
*
*
Products specifications
Attribute nameAttribute value
Master (outer) case weight156.5 lbs
Master (outer) case height12.7"
Country of OriginChina
Width17.5"
Depth20.7"
Height6.85"
Weight116.4 lbs
Battery Recharge Time6 h
Emergency Power Off (EPO)Y
Input Frequency50/60 Hz
Display TypeLED
Power factor0.9
Number of phases1
Master (outer) case length29.1"
Master (outer) case width23.6"
EMI/RFI noise filteringY
Crest factor3:1
Features
Rack capacity4U
LED indicatorsY
Output power5400 W
Noise level60 dB
Audible alarm(s)Y
Input operation voltage (min)200 V
Input operation voltage (max)240 V
Output operation voltage (min)200 V
Output operation voltage (max)240 V
Efficiency96 %
Design
CertificationUL1778 CSA FCC Part 15 Category A IEC 61000-4-5 1995 B
Form factorRackmount
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 50 °C
Operating altitude0 - 118110.2"
Relative humidity0 - 95 %
Ports & interfaces
RS-232 ports1
USB 2.0 ports quantity1
Serial ports quantity1
Technical details
Product colorBlack
Sustainability certificatesRoHS
Management platformSNMP
Power
Maximum current40 A
Output power capacity6 kVA
Packaging data
Package weight156.5 lbs
Package width23.6"
Package depth29.1"
Package height12.7"
Logistics data
Quantity per master (outer) case1 pc(s)
Battery
Typical backup time at full load2 min
Typical backup time at half load8.5 min
Hot-swap batteryY
Product tags
  • (81422)