Tripp Lite SU1500RTXLCD2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA 1350 W 6 AC outlet(s)

Tripp Lite SU1500RTXLCD2U. UPS topology: Double-conversion (Online), Output power capacity: 1.5 kVA, Output power: 1350 W. AC outlet types: NEMA 5–15R, Power plug: NEMA 5-15P, AC outlets quantity: 6 AC outlet(s). Typical backup time at full load: 4.2 min, Typical backup time at half load: 14 min. Form factor: Rackmount/Tower, Product color: Black, Housing material: Steel. Width: 17.5" (444.5 mm), Depth: 18.5" (469.9 mm), Height: 3.5" (88.9 mm)
Manufacturer: Tripp Lite
SKU: 3336887
Manufacturer part number: SU1500RTXLCD2U
GTIN: 0037332168610
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Tripp Lite Smart Online UPS systems offer high performance power protection ideal for critical server and network equipment in datacenters, computer rooms and network closets. Online, double-conversion Uninterruptible Power Supply (UPS) with Transformerless, IGBT technology maintains perfectly regulated output power by continuously converting raw AC input to DC, then re-converting output back to AC. Fully regulated sine wave AC output with +/-2% voltage regulation powers network equipment continuously, even during severe brownouts and overvoltages, all without depleting UPS battery reserves. Maintains battery-derived AC output during power failures with zero transfer time. Extended runtime options available. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Highly efficient operation in optional economy mode saves BTU heat output and energy costs. Network management interfaces support communications via USB, RS-232, contact-closure and optional SNMPWEBCARD network interface. Built-in DB9 port offers both enhanced RS-232 data and basic contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. LED display reports UPS operating mode, line power availability, battery mode operation, inverter operation, ECO mode status and output power availability. LED/LCD display panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode LCD configuration options. Programmable self-test. Fault-tolerant auto-bypass mode. Field-replaceable, hot-swappable internal batteries and external battery packs. - Tripp Lite SU1500RTXLCD2U 1500VA / 1.5kVA / 1350W on-line, double-conversion 2U rack / tower UPS - Transformerless, IGBT technology - Selectable 100/110/120/127V output (120V factory preset) - NEMA 5-15P input, 6 NEMA 5-15R outlets - Two switched 3-outlet load banks support remote reboot or programmable load shedding options - Supports 2% output voltage regulation and zero transfer time in double conversion mode - Economy mode option offers enhanced efficiency, reduced power consumption and lower BTU emissions - 14 minutes runtime at 50% load (675W) and 4.2 minutes at 100% load (1350W) with internal batteries - BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible) and BP48V27-2US (multi-pack compatible) external battery packs available (some configurations require Tripp Lite's External Battery Configuration Software) - LCD interface reports operating mode plus 9 selectable screens of UPS data (Load % & kW, Load % & kVA, Power factor, Input volts & Hz, Output volts & Hz, Battery volts and charge %, Minutes runtime, Capacity remaining, Kw/hr. consumption) - LCD interface also supports 16 screens of UPS configuration and setup options - 4 post installation hardware included, Optional 2POSTRMKITWM enables 2 post rack / wallmount installation, Optional 2-9USTAND enables tower placement - Single line TEL / Network surge suppression - Electronic bypass maintains utility output during a variety of UPS fault conditions - Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement - Frequency regulation / conversion mode offers generator-compatible frequency correction or conversion of frequency from 50 to 60Hz or 60 to 50Hz - Built-in USB, RS-232, contact-closure and optional SNMPWEBCARD accessory monitoring options - HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X - Included PowerAlert UPS monitoring software
Tripp Lite Smart Online UPS systems offer high performance power protection ideal for critical server and network equipment in datacenters, computer rooms and network closets. Online, double-conversion Uninterruptible Power Supply (UPS) with Transformerless, IGBT technology maintains perfectly regulated output power by continuously converting raw AC input to DC, then re-converting output back to AC. Fully regulated sine wave AC output with +/-2% voltage regulation powers network equipment continuously, even during severe brownouts and overvoltages, all without depleting UPS battery reserves. Maintains battery-derived AC output during power failures with zero transfer time. Extended runtime options available. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Highly efficient operation in optional economy mode saves BTU heat output and energy costs. Network management interfaces support communications via USB, RS-232, contact-closure and optional SNMPWEBCARD network interface. Built-in DB9 port offers both enhanced RS-232 data and basic contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. LED display reports UPS operating mode, line power availability, battery mode operation, inverter operation, ECO mode status and output power availability. LED/LCD display panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode LCD configuration options. Programmable self-test. Fault-tolerant auto-bypass mode. Field-replaceable, hot-swappable internal batteries and external battery packs. - Tripp Lite SU1500RTXLCD2U 1500VA / 1.5kVA / 1350W on-line, double-conversion 2U rack / tower UPS - Transformerless, IGBT technology - Selectable 100/110/120/127V output (120V factory preset) - NEMA 5-15P input, 6 NEMA 5-15R outlets - Two switched 3-outlet load banks support remote reboot or programmable load shedding options - Supports 2% output voltage regulation and zero transfer time in double conversion mode - Economy mode option offers enhanced efficiency, reduced power consumption and lower BTU emissions - 14 minutes runtime at 50% load (675W) and 4.2 minutes at 100% load (1350W) with internal batteries - BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible) and BP48V27-2US (multi-pack compatible) external battery packs available (some configurations require Tripp Lite's External Battery Configuration Software) - LCD interface reports operating mode plus 9 selectable screens of UPS data (Load % & kW, Load % & kVA, Power factor, Input volts & Hz, Output volts & Hz, Battery volts and charge %, Minutes runtime, Capacity remaining, Kw/hr. consumption) - LCD interface also supports 16 screens of UPS configuration and setup options - 4 post installation hardware included, Optional 2POSTRMKITWM enables 2 post rack / wallmount installation, Optional 2-9USTAND enables tower placement - Single line TEL / Network surge suppression - Electronic bypass maintains utility output during a variety of UPS fault conditions - Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement - Frequency regulation / conversion mode offers generator-compatible frequency correction or conversion of frequency from 50 to 60Hz or 60 to 50Hz - Built-in USB, RS-232, contact-closure and optional SNMPWEBCARD accessory monitoring options - HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X - Included PowerAlert UPS monitoring software
Products specifications
Attribute nameAttribute value
Weight45.2 lbs
Master (outer) case length19.2"
Master (outer) case width23.3"
Master (outer) case height9.2"
Country of OriginChina
Width17.5"
Depth18.5"
Height3.5"
Housing MaterialSteel
Emergency Power Off (EPO)Y
Input Frequency50/60 Hz
Cable Length118.1"
Display TypeLCD
Power factor0.9
Number of phases3
UPS topologyDouble-conversion (Online)
Master (outer) case weight63.7 lbs
Cold startY
Crest factor3:1
Features
Input operation voltage (max)127 V
Output operation voltage (max)127 V
Rack capacity2U
Cooling typeActive
LED indicatorsY
Output power1350 W
Noise level45 dB
Audible alarm(s)Y
Surge energy rating570 J
Input operation voltage (min)100 V
Output operation voltage (min)100 V
Efficiency94 %
Surge protectionY
Design
CertificationUL1778, CSA, FCC
Form factorRackmount/Tower
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Operating altitude0 - 118110.2"
Ports & interfaces
AC outlets quantity6 AC outlet(s)
AC outlet typesNEMA 5–15R
Ethernet LAN (RJ-45) ports1
RS-232 ports1
USB 2.0 ports quantity1
Power plugNEMA 5-15P
Serial ports quantity1
Modem (RJ-11) ports2
Technical details
Product colorBlack
Sustainability certificatesRoHS
Power
Maximum current20 A
Output power capacity1.5 kVA
Other features
Mac compatibilityY
Packaging data
Package depth19.2"
Package height9.2"
Package width23.3"
Package weight63.7 lbs
Bundled softwarePowerAlert
Logistics data
Quantity per master (outer) case1 pc(s)
Battery
Typical backup time at full load4.2 min
Typical backup time at half load14 min
Hot-swap batteryY
*
*
*
Products specifications
Attribute nameAttribute value
Weight45.2 lbs
Master (outer) case length19.2"
Master (outer) case width23.3"
Master (outer) case height9.2"
Country of OriginChina
Width17.5"
Depth18.5"
Height3.5"
Housing MaterialSteel
Emergency Power Off (EPO)Y
Input Frequency50/60 Hz
Cable Length118.1"
Display TypeLCD
Power factor0.9
Number of phases3
UPS topologyDouble-conversion (Online)
Master (outer) case weight63.7 lbs
Cold startY
Crest factor3:1
Features
Input operation voltage (max)127 V
Output operation voltage (max)127 V
Rack capacity2U
Cooling typeActive
LED indicatorsY
Output power1350 W
Noise level45 dB
Audible alarm(s)Y
Surge energy rating570 J
Input operation voltage (min)100 V
Output operation voltage (min)100 V
Efficiency94 %
Surge protectionY
Design
CertificationUL1778, CSA, FCC
Form factorRackmount/Tower
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Operating altitude0 - 118110.2"
Ports & interfaces
AC outlets quantity6 AC outlet(s)
AC outlet typesNEMA 5–15R
Ethernet LAN (RJ-45) ports1
RS-232 ports1
USB 2.0 ports quantity1
Power plugNEMA 5-15P
Serial ports quantity1
Modem (RJ-11) ports2
Technical details
Product colorBlack
Sustainability certificatesRoHS
Power
Maximum current20 A
Output power capacity1.5 kVA
Other features
Mac compatibilityY
Packaging data
Package depth19.2"
Package height9.2"
Package width23.3"
Package weight63.7 lbs
Bundled softwarePowerAlert
Logistics data
Quantity per master (outer) case1 pc(s)
Battery
Typical backup time at full load4.2 min
Typical backup time at half load14 min
Hot-swap batteryY
Product tags
  • (81422)